D Command table

Cmd. Sub cmd.
Data
00
see p. 157 Send frequency data (transceve)
01
see p. 157 Operatng mode selecton for transceve
02
see p. 159 Read band edge frequences
03
see p. 157 Read operatng frequency
04
see p. 157 Read operatng mode
05
see p. 157 Set operatng frequency
06
see p. 157 Operatng mode selecton for transceve
07
Select VFO mode
B0
Exchange man and sub bands
B1
Equalze man and sub bands
C0
Turn the dualwatch OFF
C1
Turn the dualwatch ON
D0
Select man band
D1
Select sub band
08
Select memory mode
0001 to
Select memory channel
0099
(0001=M-CH01, 0099=M-CH99)
0100
Select program scan edge channel P1
0101
Select program scan edge channel P2
09
Memory wrte
0A
Memory to VFO
0B
Memory clear
0E
00
Scan stop
01
Programmed/memory scan start
02
Programmed scan start
03
:
F scan start
12
Fne programmed scan start
13
Fne
22
Memory scan start
23
Select memory scan start
A1
Select
A2
Select
A3
Select
A4
Select
A5
Select
A6
Select
A7
Select
B0
Set as non-select channel
B1
Set as select channel
( The prevously set number by CI-V s set after
turnng power ON, or "1" s selected f no selec-
ton s performed.)
01
Set as select channel "★1"
02
Set as select channel "★2"
03
Set as select channel "★3"
B2
00
Set "ALL" for select memory scan
01
Set "★1" for select memory scan
02
Set "★2" for select memory scan
03
Set "★3" for select memory scan
D0
Set scan resume OFF
D3
Set scan resume ON
0F
00
Turn the splt functon OFF
01
Turn the splt functon ON
Description
:
F scan start
F scan span ±5 kHz
:
:
F scan span ±10 kHz
:
F scan span ±20 kHz
F scan span ±50 kHz
:
:
F scan span ±100 kHz
:
F scan span ±500 kHz
F scan span ±1 MHz
:
CONTROL COMMAND
Cmd. Sub cmd.
Data
10
00
Select 10 Hz (1 Hz) tunng step
01
Select 100 Hz tunng step
02
Select 1 kHz tunng step
03
Select 5 kHz tunng step
04
Select 9 kHz tunng step
05
Select 10 kHz tunng step
06
Select 12.5 kHz tunng step
07
Select 20 kHz tunng step
08
Select 25 kHz tunng step
11
00
Send/read attenuator OFF
06
Send/read 6 dB attenuator
12
Send/read 12 dB attenuator
18
Send/read 18 dB attenuator
12
0000
Send/read ANT1 selecton (RX ANT OFF)
0001
Send/read ANT1 selecton (RX ANT ON)
0100
Send/read ANT2 selecton (RX ANT OFF)
0101
Send/read ANT2 selecton (RX ANT ON)
13
00
Announce all data wth voce syntheszer
01
Announce frequency and S-meter level wth
voce syntheszer
02
Announce receve mode wth voce syntheszer
14
01
0000 to
Send/read [AF] level
0255
(0000=max. CCW, 0255=max. CW)
02
0000 to
Send/read [RF] level
0255
(0000=max. CCW, 0255=11 o'clock)
03
0000 to
Send/read [SQL] level
0255
(0000=11 o'clock, 0255=max. CW)
06
0000 to
Send/read [NR] level
0255
(0000=0%, 0255=100%)
07
0000 to
Send/read nner [TWIN PBT] poston
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
08
0000 to
Send/read outer [TWIN PBT] poston
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
09
0000 to
Send/read CW ptch
0255
( 0000=300 Hz, 0128=600 Hz, 0255=900 Hz;
5 Hz steps)
0A
0000 to
Send/read [RF POWER] level
0255
(0000=max. CCW, 0255=max. CW)
0B
0000 to
Send/read [MIC GAIN] level
0255
(0000=max. CCW, 0255=max. CW)
0C
0000 to
Send/read [KEY SPEED] level
0255
(0000=max. CCW, 0255=max. CW)
0D
0000 to
Send/read [NOTCH] poston
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
0E
0000 to
Send/read COMP level
0255
(0000=0, 0255=10)
0F
0000 to
Send/read [BK-IN DELAY] poston
0255
(0000=max. CCW, 0255=max. CW)
10
0000 to
Send/read [BAL] poston
0255
(0000=max. CCW, 0128=center, 0255=max. CW)
12
0000 to
Send/read NB level
0255
(0000=0%, 0255=100%)
14
0000 to
Send/read DRIVE gan
0255
(0000=0%, 0255=100%)
15
0000 to
Send/read Montor gan
0255
(0000=0%, 0255=100%)
16
0000 to
Send/read VOX gan
0255
(0000=0%, 0255=100%)
17
0000 to
Send/read Ant VOX gan
0255
(0000=0%, 0255=100%)
19
0000 to
Send/read BRIGHT level
0255
(0000=0%, 0255=100%)
15
01
00
Read squelch condton (squelch close)
01
Read squelch condton (squelch open)
02
0000 to
Read S-meter level
0255
(0000=S0, 0120=S9, 0241=S9+60 dB)
11
0000 to
Read RF power meter
0255
(0000=0%, 0143=50%, 0213=100%)
12
0000 to
Read SWR meter
0255
( 0000=SWR1.0, 0048=SWR1.5, 0080=SWR2.0)
13
0000 to
Read ALC meter
0255
(0000=0, 0120=Max.)
14
0000 to
Read COMP meter
0255
(0000=0 dB, 0130=15 dB, 0241=30 dB)
12