Esc. Start And Stop Value For Binary Data - CAB A+ Series Programming Manual

Hide thumbs Also See for A+ Series:
Table of Contents

Advertisement

37
37
ESC.
Start and stop value for binary data
Start and Stop value for binary data.
Syntax:
ESC.
To transmit binary data -such as graphics or fonts etc. - it is highly recommended to use this method of
data transmission. All ESC characters in a binary file have to be replaced by a double ESC (ESCESC)
to avoid unexpected reactions by the printer.
A binary constellation -for example- which contains ESC c would be interpreted as „CANCEL JOB", as
soon as it is received by the printer. Therefore all ESC characters should be exchanged.
Data transmission through ftp requires no conversion.
cab Produkttechnik GmbH & Co KG
37