Time Functions
278

[H24...]

This option is used to recall the time from the printer´s internal clock. The result will be the actual hour
on the label in the 24 hour format. Usually this option is used together with the options [MM] and
[SS] .The single digits (1..9) are printed without leading zeroes.
Syntax:
Example:
cab Produkttechnik GmbH & Co KG
Print Hour in 24-hour form (0-23)
[H24{:+HH{,+MM{,+SS}}}]
[H24...] - Print hour in 24-hour form
+HH
= adds the amount of additional hours as numerical value
+MM
= adds the amount of additional minutes as numerical value
+SS
= adds the amount of additional seconds as numerical value
m m
J
S l1;0,0,68,71,100
T 12,25,0,3,9;The hour is [H24]
A1