Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual
• Wrong printhead pressure.
- Check that the printhead is pressing against the media with a
suffi cient force, see Chapter 7.8.
• Headlift sensor out of order.
- Check the headlift sensor as described in Chapter 15.11.
Description:
Overall weak printout.
Possible Causes and Suggested Remedies:
• Various reasons.
- Check as for "No printout at all".
• Wrong Contrast/Darkness setup.
- Check setup for extremely low value.
• Wrong Paper Type/Media Sensitivity setup.
- Verify that setup matches the direct thermal media or the
combination of transfer ribbon and media.
• Wrong printhead voltage.
- Measure the +24VDC on the CPU board, see Chapter 13.4.
• Printhead pressure too low.
- Adjust as described in Chapter 7.8.
Description:
Weaker printout on either inner or outer part of label.
Possible Causes and Suggested Remedies:
• Bad printhead pressure alignment.
- Adjust the position of the headlift arm as described in Chapter 7.8.
Description:
Overall too dark printout (bleeding). Too dark a printout is particularly
troublesome when printing compact bar codes, in which case spaces
between the bars become less distinctive, and consequently less readable.
Possible Causes and Suggested Remedies:
• Wrong Contrast/Darkness setup.
- Check Contrast/Darkness setup for extremely high value.
• Wrong Paper Type/Media Sensitivity setup.
- Verify that setup matches the direct thermal media or the combi-
nation of transfer ribbon and media.
• Wrong printhead voltage.
- Measure the +24VDC on the CPU board, see Chapter 13.4.
Chapter 15—Troubleshooting
229
Need help?
Do you have a question about the EasyCoder PF2i and is the answer not in the manual?