Chapter 7—Print Mechanism
Sensor Replacement
98
Before deciding to replace the sensor, check that the sensor is free from
dust, and other objects that can block the light.
Replace the sensor as follows:
• Switch off the power, remove the power cord, and remove the front/
left-hand cover.
• Raise the printhead.
• Disconnect the sensor's cable from the CPU board.
• Pull the sensor straight out using a pair of pliers. The sensor has a
barbed shaft inserted into a hole in the center section moulding and
requires some force to come out.
• Make sure the hole is clear from any remnants of the old sensor.
• Reassemble in reverse order. The sensor's cable should be connected to
J58 (marked "HEADLIFT") on the CPU board.
• In Fingerprint, check that the sensor works properly using a PRSTAT
statement, see Intermec Fingerprint v8.xx, Programmer's Reference
Manual.
• In IPL, check that the sensor works properly using the Label Path
Open Sensor Value (<STX>L<ETX>), see IPL Programming, Reference
Manual.
Intermec EasyCoder PF2i, PF4i, and PF4i Compact Industrial—Service Manual