SCSI Test Error Codes
Continued
Error Code
Description
XXXX-40
Target timed out.
XXXX-41
SCSI bus stayed busy.
XXXX-42
ACK/REQ lines bad.
XXXX-43
ACK did not deassert.
XXXX-44
Parity error.
XXXX-50
Data pins bad.
XXXX-51
Data line 7 bad.
XXXX-52
MSG, C/D, and/or I/O lines bad.
XXXX-53
BSY never went busy.
XXXX-54
BSY stayed busy.
XXXX-60
Controller CONFIG-1 register bad.
XXXX-61
Controller CONFIG-2 register bad.
XXXX-65
Media not unloaded.
XXXX-90
Fan failure.
XXXX-91
Over Temperature.
XXXX-99
Autoloader reported tapes not
loaded properly.
Recommended Action
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
Replace the indicated device.
1. Ensure fan(s) connected.
2. Replace nonfunctional fan(s).
1. Ensure proper air flow.
2. Perform required maintenance and cleaning.
1. Install tape(s) in autoloader tape drive
according to test instructions.
2. Change autoloader magazine.
Compaq Professional Workstation AP200 Maintenance and Service Guide
4-33