CD-ROM Drive (IDE)
Error
Code
Description
3301-xx
CD-ROM drive read test failed.
3305-xx
CD-ROM drive seek test failed.
6600-xx
ID test failed.
6600-xx
ID test failed.
6605-xx
Read test failed.
6608-xx
Controller test failed.
6623-xx
Random read test failed.
Tape Drive
Error
Code
Description
1900-xx
Tape drive ID test failed.
1901-xx
Tape drive servo test failed.
1902-xx
Tape drive format or format verification test
failed.
1903-xx
Tape drive sensor test failed.
1904-xx
Tape drive BOT/EOT test failed.
1905-xx
Tape drive read test failed.
1906-xx
Tape drive write/read/compare failed.
Table 4-20
CD-ROM Drive (IDE) Test Error Codes
Recommended Action
The following steps apply to error codes error codes
3301-xx through 3305-xx and 6600-xx through
6623-xx:
1. Replace the CD media and retest.
2. Check the jumper settings on the CD-ROM drive.
3. Verify that the speaker is connected.
4. Check and/or replace the power and signal cables
5. Replace the CD-ROM drive and retest.
Table 4-21
Tape Drive Test Error Codes
Recommended Action
The following steps apply to error codes 1900-xx
through 1906-xx:
1. Replace the tape cartridge and retest.
2. Check the switch settings and terminations on the
3. Check and/or replace the signal cable and retest.
4. Replace the tape drive and retest.
5. Replace the system board and retest.
Compaq Professional Workstation AP200 Maintenance and Service Guide
and retest.
tape drive.
4-27
Need help?
Do you have a question about the AP200 and is the answer not in the manual?
Questions and answers