10. REC CH SELECT Check
Mode
Signal
Measurement Point
Measuring Instrument
Specified value
(REC CH SELECT:
CH1)
Specified value
(REC CH SELECT:
CH1•CH2)
Menu setting (AUDIO SET menu)
XLR SET
1) INPUT1 LEVEL .............................................................. MIC
2) INPUT2 LEVEL .............................................................. MIC
Checking method:
1) Input 1 kHz, +2.19 mVp-p (–60 dBs) signal in the XLR termi-
nal (INPUT1).
2) Input 2 kHz, +2.19 mVp-p (–60 dBs) signal in the XLR termi-
nal (INPUT2).
3) Set the REC CH SELECT switch to "CH1".
4) Check that the 1 kHz signal is output from the audio L termi-
nal.
5) Check that the 2 kHz signal is output from the audio R termi-
nal.
6) Set the REC CH SELECT switch to "CH1•CH2".
7) Check that the 1 kHz signal is output from the audio L termi-
nal.
8) Check that the 1 kHz signal is output from the audio R termi-
nal.
HVR-V1J/V1U/V1N/V1E/V1P/V1C
CAMERA mode
1 kHz, +2.19 mVp-p (–60 dBs) signal:
XLR terminal (INPUT1)
2 kHz, +2.19 mVp-p (–60 dBs) signal:
XLR terminal (INPUT2)
Audio L and R terminal of A/V OUT
jack
Oscilloscope
Audio L: 1 kHz signal
Audio R: 2 kHz signal
Audio L: 1 kHz signal
Audio R: 1 kHz signal
6-145