1-2-2.
Initialization of 8, 9, C, 13, 18, 1C, 1D Page Data
1. Initializing of 8, 9, C, 13, 18, 1C, 1D Page Data
Note 1: If "Initialization of Pages 8, 9, C, 13, 18, 1C, 1D" is ex-
ecuted, all data on pages 8, 9, C, 13, 18, 1C, 1D are ini-
tialized. (Only an individual page cannot be initialized)
Note 2: If the 8, 9, C, 13, 18, 1C, 1D page data has been initial-
ized, the following adjustments need to be performed
again.
1) Modification of 8, 9, C, 13, 18, 1C, 1D page data
2) Electronic viewfinder system adjustments (if all ar-
eas were initialized)
3) LCD system adjustments (if all areas were initial-
ized)
4) Node unique ID No. input (if all areas were initial-
ized)
5) Servo, RF system adjustments (if all areas were ini-
tialized)
6) Video system adjustments (if all areas were initial-
ized)
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
9
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
13
Adjustment Address
00 to FF
Adjustment Page
18
Adjustment Address
00 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Adjustment Page
1D
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
1
0
01
01
2
0
10
00
3
3
81
4
3
80
0C
5
3
80
6
Note 3: If other than adjustment address was initialized, the ad-
justed data is not initialized.
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Procedure
Set the following data, and
press PAUSE (Write) button.
(Note 3)
00: Initializing all areas
01: Initializing other than
adjustment address
Press PAUSE (Write) button.
Check the data changes to
"1C".
Perform "Modification of 8,
9, C, 13, 18, 1C, 1D Page
Data"
2. Modification of 8, 9, C, 13, 18, 1C, 1D Page Data
If the 8, 9, C, 13, 18, 1C, 1D page data has been initialized, change
the data of the "Fixed data-2" address shown in the following table
by manual input.
Processing before Modification 8, 9, C, 13, 18, 1C, 1D
page data:
Order Page Address Data
1
0
01
2
0
10
3
3
71
Modifying Method:
1) If modification of data on pages 8, 9, C, set data: 00 to page: 0,
address: 10, and then select pages 8, 9, C.
2) If modification of data on pages 13, 18, 1C, 1D, set data: 01
to page: 0, address: 10, and then select pages 3, 8, C, D.
After the modification of data finished, return the data on page:
0, address: 10 to "00".
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 8, 9, C, 13, 18, 1C, 1D
page data:
Order Page Address Data
1
0
01
2
0
10
3
3
70
4
3
70
5
2
00
6
2
01
6-10
Procedure
01
00
01
Press PAUSE (Write) button.
Procedure
01
00
10
Press PAUSE (Write) button.
Check the data changes to
"11".
29
29
Press PAUSE (Write) button.