10-2. Optical Axis Adjustment (2)
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: If reading/writing data on pages 7F, set data: 07 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 7F can be selected.
After the data reading/writing finished, return the data on page: 0,
address: 10 to "00".
A0 size (841 x 1189 mm)
SH2 or
SH2'
When the zoom at TELE end: SH1, SH2, SH3 (µsec)
When the zoom at WIDE end: SH1', SH2', SH3' (µsec)
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Pattern B
(1.2 m from the front of lens)
Video terminal of A/V jack
Oscilloscope (H period)
7F (Note 1)
52, 53
Pattern B
Black
25 mm
Fig. 6-1-11
SH1 or SH1'
SH3 or
SH3'
Fig. 6-1-12
Adjusting method:
Order Page Address Data
1
0
01
2
6
40
3
0
10
F
4
52
(7F)
F
5
53
(7F)
6
7
8
9
10
11
12
F
13
52
(7F)
F
14
53
(7F)
Note 2: Using the adjustment remote commander (HOLD switch
in NOR position), operate the zoom and focus without
touching the camcorder.
Note 3: Calculate D
52
low.
1) Calculate Y using following equations. (decimal calculation)
Y = 960 – (19.6 ÷ 18.6) × (SH2 + SH3) ÷ (SH1 × 2) × 1920
+ (1 ÷ 18.6) × (SH2' + SH3') ÷ (SH1' × 2) × 1920
2) Calculate H
using following equations. (decimal calculation)
adj
= (Y ÷ 1920) × 3916 ÷ 0.85 ÷ 0.1831
H
adj
3) Convert H
into 4-digit hexadecimal H
adj
and assume higher-order 1byte as D
as D
.
53
If H
is a positive value: Convert as it is.
adj
e.g.: When H
= 20
adj
H
' = 0014
adj
D
= 00, D
50
51
If H
is a negative value: Add 65536 and then convert it.
adj
e.g.: When H
= –20
adj
(–20) + 65536 = 65516
H
' = FFEC
adj
D
= FF, D
50
51
Processing after Completing Adjustment:
Order Page Address Data
1
0
10
2
6
40
3
0
01
6-41
Procedure
01
01
07
00
Press PAUSE (Write) button.
00
Press PAUSE (Write) button.
Set the zoom to TELE end,
and shoot the pattern B.
Adjust the focus.
Measure the SH1 (µsec), SH2
(µsec) and SH3 (µsec). (Fig.
6-1-12)
Set the zoom to WIDE end,
and shoot the pattern B.
(Note 2)
Adjust the focus. (Note 2)
Measure the SH1' (µsec),
SH2' (µsec) and SH3' (µsec).
(Fig. 6-1-12)
Calculate D
, D
52
53
D
Press PAUSE (Write) button.
52
D
Press PAUSE (Write) button.
53
and D
through the procedure given be-
53
' (signed short type),
adj
and lower-order 1byte
52
= 14
= EC
Procedure
00
00
00
. (Note 3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-v1nHvr-v1cHvr-v1jHvr-v1eHvr-v1p

Table of Contents