35. Auto White Balance Check (ND 2)
Subject
Filter
Measurement Point
Measuring Instrument
Specified Value
Note 1: Perform "Auto White Balance Adjustment" before this
adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ............................. HDV1080I
HVR-V1J/V1U/V1N/V1E/V1P/V1C
RadarW
RadarW
RadarW
Clear chart (Color reproduction
adjustment frame)
ND filter 1.0, 0.4 and 0.1
Adjusting remote commander
Data of page: 6, address: 0C is "00"
Checking method:
Order Page Address Data
1
0
01
2
6
CA
3
6
C9
4
0
10
E
5
8C
(AE)
6
0
10
OUTDOOR white balance check
7
6
01
8
6
02
9
6
0C
10
6
01
INDOOR white balance check
11
6
01
12
6
02
13
6
0C
14
6
01
InOut check
15
0
10
E
16
8C
(AE)
17
0
10
18
*19
6
13
20
6
C9
21
6
01
22
6
02
23
6
0C
24
6
01
25
Processing after Completing Adjustment:
Order Page Address Data
1
6
CA
2
6
C9
*3
6
13
4
0
01
6-61
Procedure
01
05
10
0A
01
Press PAUSE (Write) button.
00
4F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
0F
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
0A
00
Press PAUSE (Write) button.
00
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
BF
(*PAL model only)
11
4B
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
00
Press PAUSE (Write) button.
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Procedure
00
00
00
(*PAL model only)
00