Sony HVR-V1U Service Manual page 234

Digital hd video camera recorder
Hide thumbs Also See for HVR-V1U:
Table of Contents

Advertisement

2. Back Light Adjustment (OO-003 board)
Set the back light luminance.
If deviated, the image may become dark or bright.
Mode
CAMERA
Subject
Not required
Measurement Point
Pin 3 of CN1014 (EXT_DA) on
TT-003 board
Measuring Instrument
Digital voltmeter
Adjustment Page
C
Adjustment Address
32, 33
Specified Value
NORMAL mode:
BRIGHT mode:
Note: Check that the data of page: 0, address: 10 is "00".
Adjusting method:
Order Page Address Data
1
0
01
01
2
3
71
01
3
C
32
4
C
32
5
C
33
6
C
33
7
3
70
10
8
3
70
9
0
01
00
HVR-V1J/V1U/V1N/V1E/V1P/V1C
A = 0.94 ± 0.05 Vdc
B = 1.73 ± 0.05 Vdc
Procedure
Press PAUSE (Write) button.
Change the data and set the
DC voltage (A) to the
specified value of NORMAL
mode.
Press PAUSE (Write) button.
Change the data and set the
DC voltage (B) to the
specified value of BRIGHT
mode.
Press PAUSE (Write) button.
Press PAUSE (Write) button.
Check the data changes to
"11".
3. PSIG Level Adjustment (OO-003 board)
Set the uniformity improvement signal level to an appropriate level.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Check that the data of page: 0, address: 10 is "00".
Adjusting method:
Order Page Address Data
1
0
01
2
3
71
3
C
39
4
C
39
5
3
70
6
3
70
7
0
01
6-76
CAMERA
Not required
Pin 6 of CN1014 (PSIG) on TT-
003 board
Oscilloscope
C
39
A = 6.00 ± 0.05 Vp-p
Procedure
01
01
Press PAUSE (Write) button.
Change the data and set the
PSIG signal level (A) to the
specified value.
(The data should be "00" to
"7F".)
Press PAUSE (Write) button.
10
Press PAUSE (Write) button.
Check the data changes to
"11".
00
2H
Fig. 6-1-27