Sony HVR-V1U Service Manual page 187

Digital hd video camera recorder
Hide thumbs Also See for HVR-V1U:
Table of Contents

Advertisement

1-2-4.
Initialization of 7C, 7E, 7F Page Data
Note 1: If "Initialization of Pages 7C, 7E, 7F" is executed, all
data on pages 7C, 7E, 7F are initialized.
(Only an individual page cannot be initialized)
Note 2: If the 7C, 7E, 7F page data has been initialized, the fol-
lowing adjustments need to be performed again.
1) Modification of 7C, 7E, 7F page data
2) PSD sensor gradient adjustment (if all areas were ini-
tialized)
3) Optical axis adjustment (if all areas were initialized)
4) Angular velocity sensor sensitivity adjustment (if all
areas were initialized)
Adjustment Page
Adjustment Address
Adjustment Page
Adjustment Address
Adjustment Page
Adjustment Address
Initializing method:
Order Page Address Data
1
0
2
0
2
3
(72)
2
4
(72)
2
5
(72)
6
0
7
Note 3: If other than adjustment address was initialized, the ad-
justed data is not initialized.
HVR-V1J/V1U/V1N/V1E/V1P/V1C
7C
00 to FF
7E
00 to FF
7F
00 to FF
Procedure
01
01
10
07
Set the following data, and
press PAUSE (Write) button.
(Note 3)
01
2D: Initializing all areas
31: Initializing other than
adjustment address
Check the data changes to
02
"01".
01
00
Press PAUSE (Write) button.
10
00
Perform "Modification of
7C, 7E, 7F Page Data".
2. Modification of 7C, 7E, 7F Page Data
If the 7C, 7E, 7F page data has been initialized, change the data of
the "Fixed data-2" address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 7C, 7E, 7F, set data: 01 to
page: 0, address: 10, and then select pages C, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to "00".
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder
may not operate.
4) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
5) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table. If different, change them to the adjustment
initial values.
Processing after Completing Modification Camera Control
Data:
Order Page Address Data
1
0
10
2
2
00
3
2
01
6-29
Procedure
00
29
29
Press PAUSE button.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-v1nHvr-v1cHvr-v1jHvr-v1eHvr-v1p

Table of Contents