2-2. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in C
page, addresses F4, F8 and FC . The type of error indicated by the
code are shown in the following table.
Code
00
No error
10
Loading motor emergency during loading
11
Loading motor emergency during unloading
22
T reel emergency during normal rotation
23
S reel emergency during normal rotation
T reel emergency (Short circuit between S reel
24
terminal and T reel terminal)
30
FG emergency at the start up of the capstan
40
FG emergency at the start up of the drum
42
FG emergency during normal rotation of the drum
2-3. MSW Code
MSW when errors occur:
Information on MSW (mode SW) when errors occur
MSW when movement starts:
Information on MSW when movements starts when the mechanism position is moved (When the L motor is moved)
MSW of target of movement:
Information on target MSW of movement when the mechanism position is moved
Mechanical Position
UNLOAD
BL
BL LD1 (SR)
EJ
ULE
LS chassis movement section
Lock released
Cassette compartment
Position
Code
EJ
BL
ULE
LD1 (SR)
LD2 (HL)
STOP
R/P
NULL
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Emergency Type
BL
BL STOP
LD2 (HL)
Position at which the cassette component lock is released, at the farthest unload side mechanically
4
at which the mechanism can move no further in the UNLOAD direction.
E
BLANK code, at the boundary between codes.
EJECT completion position. when the cassette is ejected, the mechanism will stop at this position.
6
Cassette IN standby. The guide will start protruding out as the mechanism moves towards the
LOAD position.
When prepraing TOP load processing or when DEW is detected, rolling up tape by T reel is
2
preformed at this position.
When prepraing TOP load processing or when DEW is detected, rolling up tape by S reel is
A
preformed at this position.
Stop position in the loading state. The pinch roller separates, the tension regulator returns, and the
8
brake is imposed on both reels.
PB, REC, CUE, REVIEW, PAUSE, FF, REW positions. When pinch roller is pressed, and the
C
tension regulator is ON, the mechanism is operating at this position in modes in which normal
images are shown.
0
Code not existing in the MD. Default value.
F
Status before finding any mechanism position.
LOAD
BL
R/P
A (MSB)
B
C
D (LSB) (Fixed at Ò Ó)
Pinch roller pressing