Sony HVR-V1U Service Manual page 191

Digital hd video camera recorder
Hide thumbs Also See for HVR-V1U:
Table of Contents

Advertisement

5. Differential Gain Adjustment
5-1. Differential Gain Adjustment (1)
(Temporary Adjustment of F No.)
Perform the F No. compensation before "Differential Gain Ad-
justment (2)".
Subject
Adjustment Page
Adjustment Address
Note 1: Shoot the clear chart with the zoom TELE end.
Note 2: If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) FOCUS ................................................................... MANUAL
4) ZOOM ..................................................................... TELE end
5) REC FORMAT (Menu setting) ............................. HDV1080i
6) STEADY SHOT (Menu setting) ..................................... OFF
7) D. EXTENDER (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
1
0
2
6
3
6
4
6
5
6
6
6
7
6
8
6
Note 4: The adjustment data will be automatically input to page:
6D, address: 60 to 6F.
Processing after Completing Adjustment:
Order Page Address Data
1
6
2
6
3
6
4
6
5
0
HVR-V1J/V1U/V1N/V1E/V1P/V1C
RadarW
RadarW
RadarW
Clear chart (All white) (Note 1)
6D
60 to 6F
Procedure
01
01
17
10
C9
10
10
80
D2
60
D3
40
Press PAUSE button. (Note
01
BB
4)
Check the data changes to
02
"01".
Procedure
17
00
C9
00
10
00
01
00
Press PAUSE button.
01
00
5-2. Differential Gain Adjustment (2)
Correct the dispersion of between the channels of CMOS imager.
Subject
Adjustment Page
Adjustment Address
Note 1: Shoot the clear chart with the zoom TELE end.
Note 2: If reading/writing data on pages 6D, 6E set data: 06 to
page: 0, address: 10, and then select pages: D, E. By this
data setting, the pages 6D, 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) ZOOM ..................................................................... TELE end
4) REC FORMAT (Menu setting) ............................. HDV1080i
Adjusting method:
Order Page Address Data
1
0
01
2
6
2C
3
6
40
4
6
D0
5
6
D2
6
6
D3
7
6
D6
8
6
01
9
6
02
Note 4: The adjustment data will be automatically input to page:
6D, address: 00 to 1D and page: 6E, address: 00 to EF.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
2C
3
6
40
4
0
01
6-33
RadarW
RadarW
RadarW
RadarW
RadarW
Clear chart (All white) (Note 1)
6D
6E
00 to 1D
00 to EF
Procedure
01
01
01
60
01
01
10
Press PAUSE (Write) button.
F5
(Note 4)
Check the data changes to
"01".
Procedure
00
Press PAUSE (Write) button.
00
00
00

Advertisement