7-2. Flange Back Adjustment (2)
Perform this adjustment after performing "Flange Back Adjust-
ment (1)".
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified value
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to "00".
Note 3: Check that the data of page: 6, address: 02 is "00". If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4: Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ...................................................................... OFF
3) REC FORMAT (Menu setting) ............................. HDV1080i
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
HVR-V1J/V1U/V1N/V1E/V1P/V1C
RadarW
RadarW
RadarW
RadarW
RadarW
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Adjusting remote commander
6F
11, 20 to 3F, 4C, 4D
Data of page: 6F, address: 2F is"00" to "0E"
Data of page: 6, address: 0C is"00"
Adjusting method:
Order Page Address Data
1
0
01
2
6
64
3
0
10
E
4
8C
(AE)
5
0
10
6
6
01
7
8
9
6
01
10
6
02
11
6
0C
12
0
10
F
13
2F
(6F)
14
0
10
Note 5: The adjustment data will be automatically input to page:
6F, address: 11, 20 to 3F, 4C, 4D.
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
01
3
6
02
4
6
01
5
6
64
6
0
10
E
7
8C
(AE)
8
0
10
9
0
01
10
6-37
Procedure
01
04
0A
01
Press PAUSE (Write) button.
00
13
Press PAUSE (Write) button.
Wait for 2 seconds.
Place ND filter on the lens so
that the optimum image is
obtain.
Press PAUSE (Write) button.
29
(Note 5)
Check the data changes to "01".
Check the data is "00".
06
Check the data is "00" to "0E".
00
Procedure
00
Press PAUSE (Write) button.
25
Press PAUSE (Write) button.
Check the data changes to "01".
00
Press PAUSE (Write) button.
00
0A
00
Press PAUSE (Write) button.
00
00
Perform "Flange Back
Check".