40. Color Reproduction Check (Indoor SD: ND 1)
RadarW
RadarW
RadarW
Subject
Color bar chart (Color reproduction
adjustment frame)
Measurement Point
Video terminal of Adjusting remote
A/V jack
(75 Ω terminated)
Measuring Instrument
Vectorscope
Specified Value
All color
luminance
points should
settle within each
color
reproduction
frame.
Note 1: Perform "Color Reproduction Adjustment" before this
adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 1
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ......................................... DV
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Checking method:
Order Page Address Data
1
2
commander
3
4
5
Data of page: 6
6
address: 0C is
"00"
7
8
9
10
11
12
Processing after Completing Adjustment:
Order Page Address Data
1
2
3
4
5
6
7
6-66
0
01
01
0
10
0A
E
8C
01
Press PAUSE (Write) button.
(AE)
0
10
00
6
C9
10
6
CA
04
6
D0
48
6
01
4D
Press PAUSE (Write) button.
Check the data changes to
6
02
"01".
6
0C
Check the data is "00".
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
Check that the each color
luminance point is in each
color reproduction frame.
6
01
00
Press PAUSE (Write) button.
6
CA
00
6
C9
00
0
10
0A
E
8C
00
Press PAUSE (Write) button.
(AE)
0
10
00
0
01
00
Procedure
Procedure

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hvr-v1nHvr-v1cHvr-v1jHvr-v1eHvr-v1p

Table of Contents