I. STANDARDS AND ADJUSTMENTS
A.

Electrical System

1
When Replacing the DC Controller PCB
• Without the Reader Unit Installed (with the printer board installed)
1) Connect the power plug to the power outlet; and while holding on the "Menu key,
Enter/Online key, and Cancel key" on the control panel at the same time until "Start
SELF-TEST" displays. The panel displays will show "Display" to indicate that service
mode has started after the printer unit checks itself.
2) Using the Menu key on the control panel, select "READ MEMORY".
3) Press the ENTER key to select "READ FROM DCON".
4) Using the
or
5) Press the ENTER key to execute.
6) See that "READ FROM DCON EXECUTING>" is indicated.
7) Turn off the printer unit power switch and disconnect the power plug.
8) Perform the steps under VIII.C.4 "Removing the DC Controller PCB" in Chapter 4 to
remove the DC controller PCB and mount the new DC controller PCB.
9) Put back the parts that have been removed. (However, it is better not to mount the
rear cover of the printer unit until after checking to see that copier operates normal-
ly.)
10)Connect the power plug to the power outlet; and enter the service mode once agein.
11)Using the Menu key on the control panel, select "WRITE MEMORY".
12)Press the ENTER key to select "WRITE TO DCON".
13)Using the
or
14)Press the ENTER key to execute.
15)See that "WRITE TO DCON EXECUTING>" is indicated.
16)End.
Reference:
For details of "READ MEMORY" and "WRITE MEMROY," see p. 10-88 and p. 10-92.
COPYRIGHT © 1999 CANON INC.
Download free service manual at http://printer1.blogspot.com
key, select 'YES'.
key, select 'YES'.
CANON 660/2100 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)