Canon CP660 Service Manual page 383

Table of Contents

Advertisement

Code
The internal communication has an
error.
E197
E198
The IC on the DC controller PCB has
an error.
• The communication between the DC
controller PCB and the reader con-
troller PCB is faulty.
• The communication between the DC
controller PCB and the PS/PCL
E240
board or between the reader con-
troller PCB and the PS/PCL board is
faulty.
The bin flapper 1 of the sorter-H1 is
faulty.
E545
*4
*4
The bin flapper 2 of the Sorter-H1 is
faulty.
E546
The initial communication between
the ACC controller PCB and an
E677
accessory has an error.
*3
The communication between the ACC
controller PCB and an accessory has
E678
been interrupted.
*3
The protocol used for communication
E679
between the ACC controller PCB and
*3
an accessory has an error.
COPYRIGHT © 1999 CANON INC.
Download free service manual at http://printer1.blogspot.com
Cause
CANON 660/2100 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 TROUBLESHOOTING
Description
A machine internal communication
error occurs more than once. Or, the
reception interruption on the DC con-
troller side does not occur for a spe-
cific time for internal communication.
The IC on the DC controller PCB has
an error.
• The DPPRDY signal is not sent for
0.25 sec or more from the reader
controller to the DC controller PCB
after the DC controller PCB is sup-
plied with power.
• The signals between the PS/PCL
board and the DC controller PCB or
between the PS/PCL board and the
reader controller PCB cannot be
exchanged for a specific time after
the PS/PCL board is supplied with
power.
The bin flapper solenoid sensor
(PI12) does not detect solenoid oper-
ation even when the solenoid (SL3) is
driven during initialization or face-
down delivery. Or, the bin flapper sen-
sor remains on even when the sole-
noid has stopped operation.
The bin flapper solenoid sensor
(PI12) does not detect solenoid oper-
ation even when the solenoid (SL4) is
driven during initialization or face-
down delivery. Or, the bin flapper sen-
sor remains on even when the sole-
noid has stopped operation.
• The ACC controller PCB and the
accessory fail to become ready for
communication in 4 sec (possibly, a
problem in the power supply).
• An initial communication error with
each accessory has occurred.
• The accessory is turned off in the
middle of communication.
• The cable of the accessory has
been disconnected in the meddle of
communication.
The read/write/parity check of data is
faulty, and communication fails to end
within a specific time.