C.

Protective Mechanisms

The +24 VB power supply circuit and the +5 V power supply circuit are equipped with
an overcurrent protective mechanism and an overvoltage protective function, which auto-
matically shuts off output voltage to prevent damage to the power supply circuits in the
event that a load should suffer a short circuit or overcurrent/overvoltage.
If the overcurrent protective mechanism or the overvoltage protective mechanism
turns on to cut of the DC voltage from the low-voltage power supply circuit, turn off the
power switch, disconnect the power cable, and correct the fault on the load in question;
then, connect the power cable, and turn on the power switch.
The circuit is quipped with a circuit breaker (CB101) and a fuse (F1), which shut off
the output voltage in response to overcurrent (i.e., CB101 turns off). If such has occurred,
wait about 60 sec and then turn on the power once again.
Note that an overvoltage blows F1 to shut off the power.
COPYRIGHT © 1999 CANON INC.
Download free service manual at http://printer1.blogspot.com
CANON 660/2100 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)