Figure 36: Removing The Nut From The Grounding Post; Figure 37: Installing The Grounding Wire - Allied Telesis AT-x510-28GPX Installation Manual

Allied telesis x510 series gigabit ethernet switches
Hide thumbs Also See for AT-x510-28GPX:
Table of Contents

Advertisement

Figure 36. Removing the Nut from the Grounding Post
Note
Remove only the top nut from the grounding post. If necessary, use
a second 7mm wrench to hold the bottom nut still while removing the
top nut.
4. Attach the grounding lug and wire to the grounding post and secure
them with the nut removed in Step 3, and a 7mm wrench. Allied
Telesis recommends tightening the nut to 15 in-lbs. Refer to Figure 37.
Figure 37. Installing the Grounding Wire
x510 Series Installation Guide for Stand-alone Switches
79