6. Remove 6.5mm (0.25 in.) of insulation from one end of the red
-48/-60VDC wire. Refer to Figure 41 on page 82.
7. Insert the red -48/-60VDC wire into the left connector and secure it by
tightening the captive screw with a flat-head screwdriver. Allied Telesis
recommends tightening the screw to 5 in-lbs. Refer to Figure 43.
Figure 43. Inserting the -48/-60VDC Wire
8. Slide the DC connector into the slot on the switch. Refer to Figure 44.
Figure 44. Sliding the DC Connector into the Switch
x510 Series Installation Guide for Stand-alone Switches