Maximum Distance; Cable Requirements; Port Pinouts; Table 1: Twisted Pair Cable For The 10/100/1000Base-T Ports - Allied Telesis AT-x510-28GPX Installation Manual

Allied telesis x510 series gigabit ethernet switches
Hide thumbs Also See for AT-x510-28GPX:
Table of Contents

Advertisement

Chapter 1: Overview
Maximum
Distance
Cable
Requirements

Port Pinouts

26
You may set the wiring configurations of the ports manually or let the
switch configure them automatically with auto-MDI/MDI-X (IEEE 802.3ab-
compliant). This feature enables the switch to automatically negotiate with
network devices to establish their proper settings.
The MDI and MDI-X settings do not apply when ports are operating at
1000 Mbps.
The ports have a maximum operating distance of 100 meters (328 feet).
The cable requirements of the ports are given in Table 1.
Table 1. Twisted Pair Cable for the 10/100/1000Base-T Ports
Cable Type
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Note
For the cable requirements for the ports on the AT-x510-28GPX,
AT-x510L-28GP, AT-x510-52GPX, and AT-x510L-52GP Switches
for PoE devices, refer to Table 3 on page 28.
Refer to Table 18 on page 106 and Table 19 on page 106 for the port
pinouts of the 10/100/1000Base-T twisted pair ports.
10Mbps
100Mbps
Yes
Yes
Yes
Yes
Yes
Yes
1000Mbps
No
Yes