Service Information - KYMCO VENOX 250 Service Manual

Hide thumbs Also See for VENOX 250:
Table of Contents

Advertisement

16
. CHARGING SYSTEM

SERVICE INFORMATION

GENERAL INSTRUCTIONS
• Do not quick charge the battery. Quick charging should only be done in an emergency.
• Remove the battery from the motorcycle for charging. If the battery must be charged on the
motorcycle, keep sparks and flames away from a charging battery. The hydrogen gas produced
by a charging battery is very flammable and can explode.
• When inspecting the A.C. generator, use an electric tester.
• Route the charging system wires properly to avoid short-current due to wires being twisted or
kinked.
SPECIFICATIONS
Battery
A.C. generator
Regulator/Rectifier
Charging coil resistance for ACG
TORQUE VALUES
A.C. generator stator screw
A.C. generator flywheel nut
SPECIAL TOOLS
Flywheel holder
Flywheel puller
TESTING INSTRUMENTS
Electric tester
Battery capacity
Electrolyte specific gravity
Charging current
Start charging rpm
Charging performance
Limit voltage
Type
0.8~1.2 kg-m
7.5~8.5 kg-m
VENOX 250
12V8AH
1.32
Less than 0.9A
900 rpm (min.)
10.5A min. / 1500 rpm
17~20A / 5000 rpm
14.5 0.5V/5000 rpm
Three-way wave rectifier /
Regulate auto in the SCR
0.301Ω~0.559Ω