Fan Motor Inspectment; Thermostatic Switch Inspectment; Radiator Installation - KYMCO VENOX 250 Service Manual

Hide thumbs Also See for VENOX 250:
Table of Contents

Advertisement

11
. COOLING SYSTEM

FAN MOTOR INSPECTMENT

Check fan motor by battery.
THERMOSTATIC SWITCH
INSPECTMENT
When coolant temperature lower then 90±2
the thermostatic switch OFF.
When coolant temperature over 90±2
thermostatic switch ON.

RADIATOR INSTALLATION

The installation sequence is the reverse of
removal.
Connect the overflow tube and secure with
the tube clamp.
Connect the air vent tube to the radiator
filler.
Fill the radiator with coolant.
After installation, check for coolant leaks.
If you want to refill the coolant, the
following procedure must be checked.
1.Then start the engine, filled in the
coolant till the coolant flowed out from
the air vent tube.
2.Check if no bubble in the radiator filler.
3.Put the bypass tube on.
the
Overflow Tube
VENOX
250
Air Vent Tube
11-6