p68 Ver. 3.003 (24/4/03)
ADDRESS
DEFAULT
(Data Type)
898
(Option Data)
1 - Yes
2 - Yes
3 - Yes
4 - No
5 - Yes
6 - Yes
7 - Yes
8 - No
899
(Option Data)
1 - Yes
2 - Yes
3 - Yes
4 - Yes
5 - Yes
6 - Yes
7 - No
FUNCTION
SYSTEM INPUT DIALER ENABLE
Dialer reporting for various System Inputs can be enabled by selecting the required System Input dialer enable options.
1 - AC fail
2 - Low battery
3 - Cabinet Tamper
4 - Keypad Lockout
5 - Comm Fail / System Reset / Real-Time-Clock Problem
6 - Siren Monitor
7 - PWR Fuse / Battery fuse
8 - Zone Self-test Fail
EMERGENCY OPTIONS
These options determine how the PANIC, FIRE, MEDICAL, and DURESS alarms will be processed.
These settings will affect:
-
Panic alarms generated by Keypad Panic AND Zone Inputs programmed as the "24 Hour Panic" Zone Type. (Zone Type 12)
-
Fire alarms generated by Keypad Fire. (Siren & Dialer options for "24Hr Fire Zones are determined by Zone Options)
-
Medical alarms generated by Keypad Medical.
-
Duress alarms generated by Keypad Duress AND Zone Inputs programmed as the "24Hr Duress" Zone Type. (Zone Type 13)
1 - Panic alarms will activate the Siren.
2 - Panic alarms will activate the Dialer.
3 - Fire alarms will activate the Siren.
4 - Fire alarms will activate the Dialer.
5 - Medical alarms will activate the Siren.
6 - Medical alarms will activate the Dialer.
7 - Duress alarms will activate the Dialer.
When enabled, the Emergency alarms generated by the Keypad do not activate the "FAULT" Lamp. However, "View Fault History"
(<NEXT> 13) can be used to view any Keypad Emergency Alarms that have occurred in the last 5 Arming periods.
CONCEPT IQ. PLUS Programmer's Manual.