4.
PROGRAM ANY ADDITIONAL BASIC OPTIONS FOR ZONE INPUTS.
Zone
1
2
3
Address
651
652
653
1
Silent
2
Siren Lockout
7
Change Sense
(Normally Open Contacts)
5.
PROGRAM THE SIREN SWINGER SHUTDOWN COUNT.
DEFAULT: 16
(Only required if the "Siren Lockout" option is selected for any Zones in the Zone Options above)
Program the number of times (0 to 255) the Siren can be triggered by a Zone Input in a single Arming period before Siren Lockout occurs.
(The counter is reset when the Area is turned Off)
6.
ENABLE/DISABLE THE SYSTEM INPUT ALARMS THAT ARE REQUIRED TO ACTIVATE THE SIREN.
1
AC Fail.
3
2
Low Battery
4
7.
ENABLE/DISABLE THE KEYPAD EMERGENCY ALARMS THAT ARE REQUIRED TO ACTIVATE THE SIREN.
1
Panic Alarms will activate the Siren.
3
Fire Alarms will activate the Siren.
5
Medical Alarms will activate the Siren.
4
5
6
7
8
654
655
656
657
658
When selected, Siren is not activated when an alarm is triggered on this Zone. (NOTE: "Silent" over-rides "Siren Lockout")
Zone will only trigger the Siren for the number of times specified in the "Siren Swinger Shutdown Count". (Address 013)
The "Sealed" and "Alarm" states are swapped so that an alarm is triggered when an Open to Closed transition occurs on the detector contacts.
May be required for smoke detectors, etc.
Cabinet Tamper. (Enabled by default)
Keypad Lockout.
Enabled by default
Enabled by default
Enabled by default
9
10
11
12
13
659
660
661
662
663
t
t
5
Comms Fail / System Reset / Real-time Clock Problem.
6
Siren Monitor
t
t
CONCEPT IQ. PLUS Programmer's Manual.
14
15
16
664
665
666
7
PWR Fuse / Battery Fuse.
NEXT 651 to 666
NEXT 913
NEXT 897.
NEXT 899.