CONCEPT IQ. PLUS Programmer's Manual.
ADDRESS
DEFAULT
(Data Type)
891
(Option Data)
1 - No
2 - Yes
3 - Yes
4 - No
5 - No
6 - No
7 - No
8 - No
FUNCTION
GENERAL OPTIONS. 2.
1 - Multi-Area System.
2 - Terminal Beeper for Day Alarms.
3 - Bell Squawk on Siren for Wireless Remote Key operations.
4 - All Area Siren Off control.
5 - DTMF Control.
6 - Delay Siren until Comms complete.
7 - Enable Call Forwarding.
8 - Dialer enabled in Home Mode.
Multi-Area System.
The system is designed to operate in Single Area or Multi-Area mode.
•
In Single Area mode the system only uses one Area, the "General Area" or "Area 1". When Single Area mode is selected, the Area
Lamps on the Terminal are not used and any Multi-Area programming or operating functions are ignored.
•
When Multi-Area mode is selected, up to four separate Areas can be used. The Area Lamps on the Terminal indicate the status of
each individual Area. NOTE: If an Entry/Exit Area is required in a Multi-Area system, Area 1 is recommended.
Bell Squawk on Siren for Wireless operations.
Arm (Button 1) - 1 Squawk.
DTMF Control. IMPORTANT NOTE!
When this option is selected, remote connection for Upload/Download is not available, except via the Answer Call operation, NEXT 35.
Delay Siren until Comms complete.
When enabled, the Siren Timer &/or Siren Hold-off timer is not initiated until after successful communications has been completed or a
Comms Fail system alarm is activated.
If this option is enabled, note that the Siren will be delayed until after the "Maximum number of Dial Attempts" (Address 508) is reached.
Care should be exercised when enabling this option if a higher number of "Maximum Dial Attempts" is programmed.
On some sites it may be possible for high numbers of Zone alarms being reported, to delay the Sirens for an unacceptable length of time.
In this instance it is recommended to select "Dialer Lockout" (Address 651-666, Option 3) in the Zone Options, and set the Dialer Swinger
Shutdown Count (Address 914) to a low value to minimise the number of "hits" reported for each Zone.
Call Forwarding.
If "Call Forwarding is enabled, the "Call Divert" (Address 502) and "Un-divert" Telephone numbers (Address 503) must be programmed.
Provides Door Bell sound on all Terminals associated with the Area the Day Alarm Zone is in.
Allows any User with any Area Off permissions to cancel the Siren by entering their PIN code.
Allows Dial-up remote control from any touch-tone (DTMF) telephone. See note below.
"Squawk" is 200mS Tone burst in a 1 second period.
Disarm (Button 2) - 2 Squawks.
Error (Already Armed) - 5 Squawks.