CONCEPT IQ. PLUS Programmer's Manual.
ADDRESS
DEFAULT
(Data Type)
525-530
Spare
(Value Data)
531
30 Seconds
532
30 Seconds
533
30 Seconds
534
30 Seconds
535-540
Spare
(Value Data)
541
60 Seconds
542
60 Seconds
543
60 Seconds
544
60 Seconds
545-550
Spare
(Value Data)
FUNCTION
AREA ENTRY DELAY PROGRAMMING.
These Addresses set the Entry time to be applied to Zone Inputs programmed as Delayed Zones.
i.e. Zone Types
1 (Delayed),
5 (Away Delayed/Home Isolate),
GENERAL AREA / AREA 1 ENTRY DELAY TIME
AREA 2 ENTRY DELAY TIME
AREA 3 ENTRY DELAY TIME
AREA 4 ENTRY DELAY TIME
AREA EXIT DELAY PROGRAMMING.
These Addresses set the Exit time to be applied to Zone Inputs programmed as Delayed Zones.
i.e. Zone Types 1 (Delayed) and 2 (Handover).
GENERAL AREA / AREA 1 EXIT DELAY TIME
AREA 2 EXIT DELAY TIME
AREA 3 EXIT DELAY TIME
AREA 4 EXIT DELAY TIME Note: Area 4 Exit Delay is not used when Armed as a Sub-Area. The controlling Area Exit Delay is used.
AREA 1 TO AREA 4 ARMING OPTIONS (TIMEZONE CONTROL)
The Area Arming options allow a TimeZone to be assigned to the Area causing the Area to automatically Arm when the TimeZone goes
Valid.
Note that when the TimeZone goes Valid and the Area Arms, it does not force the Area to remain in the Armed state for the duration of the
Valid period.
2 (Handover),
6 (Away Delayed/Home Delayed) and
Ver. 3.003 p51