CONCEPT IQ. PLUS Programmer's Manual.
No Reporting.
Go to Step 30
"User Programming"
t
t
How to Enter Data. Select Address: Key in the Installer PIN Code; Press
Enter Data:
Enter the new Data
26.
PROGRAM THE DIALER SWINGER SHUTDOWN COUNT.
DEFAULT: 16
(Only required if the "Dialer Lockout" option is selected for any Zones in the Zone Options in Step 25 above)
Program the number of times (0 to 255) the Dialer can be triggered by a Zone Input, in a single Arming period, before Siren
Lockout occurs.
(The counter is reset when the Area is turned Off)
27.
ENABLE/DISABLE ANY GENERAL OPTIONS THAT ARE REQUIRED FROM "GENERAL OPTIONS 2".
Option
6
Delay Siren until Comms complete.
8
Dialer enabled in Home Mode.
28.
ENABLE/DISABLE THE SYSTEM INPUT ALARMS THAT ARE REQUIRED TO ACTIVATE THE DIALER.
Option
1
AC Fail.
2
Low Battery.
3
Cabinet Tamper.
4
Keypad Lockout.
5
Comms Fail / System Reset.
6
Siren Monitor.
7
PWR Fuse / Battery Fuse.
8
Zone Self-Test Fail.
then enter the 3 digit Address
.. (1-16 digits) OR Option/s to Select/De-select
t
Default
Description
No
Siren operation will not be initiated until a report has been sucessfully
sent, or a Comms Fail alarm generated.
No
If selected, Alarms and Open/Close reports will be sent for Areas armed
in Home Mode.
t
Default
Option
Yes
15
Door Forced
Yes
Yes
No
Yes
Yes
Yes
No
t
(A1 to A3 Lamps will flash to prompt for each digit). The current Data will be displayed.
, then
.
NOTE:
clears the current field of all data or settings ready for new data.
Ver. 3.003 p29
NEXT 914
NEXT 891
NEXT 898.
Default
NO