Disassembly

5.4 Front Cover

(PL 8.1.22)
1.
Open the front cover and remove the toner
cartridge.

5.5 Scanner Assembly

(PL 8.5)
1.
First remove:
a.
Rear cover, see page 5-2.
b.
Side covers, see page 5-3.
c.
To replace the OPE (Control Panel) Assembly,
do steps 6 and 7 only.
d.
To remove the Scan Upper, remove the ADF
then do steps 8 and 9 only.
e.
To remove the CCD Module, remove the ADF
then do steps 10 through 11.
f.
To remove the Drive Motor, remove the ADF
then do steps 8, 9, 12 and 14.
g.
To remove the Open Sensor, remove the ADF
then do steps 8, 9, 15 and 16.
5-4
WorkCentre PE 120/120i
2.
Unclip the front cover from the frame and remove.
Front Cover
2.
Remove 2 screws securing the scanner assembly.