5.
Remove 2 screws securing the upper cover, and
remove the cover.
Upper Cover

5.7 OPE (Control Panel)

(PL 8.4)
1.
First remove:
a.
Rear cover, see page 5-2.
b.
Side covers, see page 5-3.
c.
Steps 6 and 7 on page 5-4.
2.
Remove 10 screws securing the control panel cover
to the control panel board.
6.
Unplug 1 connector and remove 5 screws securing
the ADF motor assembly. Remove the motor.
Note
Before removing the motor assembly, note the
position of the ferrite and harness routing.
Replacement Notes:
Caution
When refitting the ADF motor assembly, ensure
the harness and ferrite are properly located and
clear of the motor fan and white bar clip.
Service Manual
ADF Motor Ass'y
ADF Lower Ass'y
OPE Cover
OPE PBA