Kx-Td308 Software Verification And Programming For Dpt Integration Via The Manager's Extension - Panasonic KX-TVS95 Installation Manual

Voice processing system
Hide thumbs Also See for KX-TVS95:
Table of Contents

Advertisement

4.5 CONNECTING THE VPS WITH THE PANASONIC KX-TD816, KX-TD1232, KX-TA1232 AND KX-TD308
7.
Follow steps 5-12 in 4.5.1 KX-TD1232 Software Verification and Programming for DPT
Integration via the Manager's Extension.
The required programming is now complete and the VPS and KX-TD1232 should be able
to communicate through DPT Integration.
Before starting up the VPS, please be sure to install the required extension cards and
telephones to the KX-TD1232.
When running the Quick Setup command (Section 5 CUSTOMIZING THE SYSTEM) from
the VPS, the PBX transmits the station information automatically. This saves time when
programming the VPS.
4.5.3
KX-TD308 Software Verification and Programming for
DPT Integration via the Manager's Extension
It is important that the KX-TD308 has the proper software level to allow DPT Integration with
the VPS. Follow the procedures below to confirm the software level, then complete the
required programming before starting up the VPS.
All of the following procedures must be done after entering system programming. Refer
to the KX-TD308 Programming Guide or Installation Manual for instructions on how to
enter the system programming mode.
Software Verification
1.
Verify Software—check the software version of the KX-TD308 using System Program
[116].
Example: P871FYMMDDA
The underlined digits represent the software production date code (year, month, day). For
DPT Integration, the software version of the PBX must be P871F or higher.
If the software version of the PBX is lower than this, you may not be able to utilize
some of the features available only with DPT Integration. For more information, call
National Parts Center at 1-800-833-9626.
From the SYS-PGM NO ? screen:
a)
Enter [116].
b)
Press the NEXT button (SP-PHONE).
c)
The system displays the ROM version and the date it was created.
This version must be P871F or higher for DPT Integration to be utilized.
2.
Set the date and time using System Program [000].
3.
Set PBX extension numbering using System Program [003].
114
Installation Manual

Advertisement

Table of Contents
loading

Table of Contents