2B-9 Power Trim and Tilt:

Diagnose PTT System Malfunction

Condition
Motor will not trim / tilt at
all (no up, no down).
Motor will not trim / tilt up. Defective PTT switch.
Motor will not trim / tilt
down.
PTT motor operates, but
no motor trim / tilt
movement.
Motor will not retain
selected trim and tilt
setting, creeps
downward.
PTT motor operates at
higher than normal speed,
or with high pitched
"squealing" sound. No
trim / tilt action.

Diagnostic Information and Procedures

Possible cause
Blown fuse for PTT system.
(Main: 30 A, PTT switch: 15 A, ECM: 30
A).
Defective PTT switch.
Open circuit between main fuse 30 A
and PTT relay.
Defective main relay.
Defective PTT relay.
Defective ECM and/or PTT system
circuit.
Loose or corroded battery cable
connection.
Open circuit between main fuse and
starter motor magnetic switch.
Defective PTT motor armature.
Defective PTT motor armature brushes. Replace.
Defective PTT pump.
Manual release valve leaking.
Defective PTT relay.
Open light blue lead wire circuit.
Defective ECM.
Defective PTT switch.
Defective PTT relay.
Open pink lead wire circuit.
Defective ECM.
Low PTT fluid level.
Manual release valve leaking.
Debris in system.
Broken drive joint in PTT pump.
Broken PTT pump.
Tilt piston leaking.
Manual release valve leaking.
Tilt piston leaking.
Debris in system.
Low PTT fluid level.
Manual release valve leaking.
Broken drive joint in PTT pump.
Correction / Reference Item
Inspection and replace.
Replace.
Repair.
Replace.
Replace.
Inspection of ECM and its circuit in section 1A.
Repair or retighten.
Repair.
Replace.
Replace.
• Ensure that valve is fully closed.
• Inspect manual release valve.
Replace.
Replace.
Repair or replace.
Replace.
Replace.
Replace.
Repair or replace.
Replace.
Added PTT fluid.
• Ensure that valve is fully closed.
• Inspect manual release valve.
Inspect for debris.
Replace.
Replace.
Replace PTT unit assembly.
• Ensure that valve is fully closed.
• Inspect manual release valve.
Replace PTT unit assembly.
Inspect for debris.
Added PTT fluid.
• Ensure that valve is fully closed.
• Inspect manual release valve.
Replace.
ZAJ6112204001