Battery Requirement Description; Component Location; Charging System Components Location; Diagnostic Information And Procedures - Suzuki GF60A Service Manual

Table of Contents

Advertisement

Battery Requirement Description

Refer to "Battery Requirement" in Section 0A (Page 0A-5).

Charging System Components Location

Refer to "Wiring Harness Routing Diagram" in Section 4A (Page 4A-4).

Charging System Diagnosis

Condition
Alternator (Battery charge
coil) does not charge.
Alternator (Battery charge
coil) overcharge.
Unstable charging

Component Location

Diagnostic Information and Procedures

Possible cause
Open or short circuit lead wires.
Open or short circuit battery charge coil. Replace.
Rectifier/Regulator failure.
Main fuse blown out.
Poor or broken battery connection.
Rectifier/Regulator failure.
Poorly grounded rectifier/regulator.
Short circuit battery charge coil.
Loose lead wire connection.
Rectifier/regulator failure.
Poor or broken battery connection.
Charging System:
Correction / Reference Item
Repair or replace.
Replace.
Replace.
Repair or Replace.
Replace.
Repair or Retighten.
Replace.
Repair or replace.
Replace.
Repair or replace.
1K-2