Scan Log Dump Progress Codes

Table 10. Scan Log Dump Progress Codes
Error Code
D130 xxxx

Problem Determination-Generated Error Codes

Attention:
corrected, go to "MAP 1540: Minimum Configuration" on page 57 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to "MAP
410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic Information for
Multiple Bus Systems.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 11. Problem Determination Generated Error Codes
Error Code
M0BT 0000
M0BT 0001
M0KB D000
248
Service Guide
Description
Scan log dump in progress
If you replace FRUs or perform an action and the problem is still not
Description
The system hung during speaker
POST. This error code is generated
by the customer performing "Problem
Determination" in the RS/6000
Enterprise Server Model F80,
Eserver pSeries 620 Models 6F0
and 6F1 User's Guide.
The system hung during "Starting
Software...". This error code is
generated by the customer
performing "Problem Determination"
in the RS/6000 Enterprise Server
Model F80, Eserver pSeries 620
Models 6F0 and 6F1 User's Guide.
The system hung during keyboard
POST. This error code is generated
by the customer performing "Problem
Determination" in the RS/6000
Enterprise Server Model F80,
Eserver pSeries 620 Models 6F0
and 6F1 User's Guide.
Action/ Possible Failing FRU
Informational message only. As the dump
progresses, the xxxx characters in the
display will change. When the scan log
dump is complete, the system may
reboot, depending on the reboot policy
settings.
Action/ Possible Failing FRU
Go to "MAP 1540: Minimum
Configuration" on page 57.
Go to "MAP 1540: Minimum
Configuration" on page 57.
Keyboard