Table 5. SPCN Error Codes (continued)
Error Code
1011 1531
1011 1532
1011 1533
1011 1534
1011 1536
1011 1611
1011 1612
1011 1613
1011 1621
1011 1622
1011 1623
112
Service Guide
Description
Power supply 3
Power supply 3
Power supply 3
Power supply 3
Power supply 3 missing
CEC regulator 1 fault
CEC regulator 1 non-power fault
CEC regulator 1 domain fault
CEC regulator 2 fault
CEC regulator 2 non-power fault
CEC regulator 2 domain fault
Action/ Possible Failing FRU
1. Power supply 3
Location: V3
2. If the problem is not resolved,
reinstall the original supply in
location V3. Then replace power
supply 1, location V1, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 2, location V2, with the
new supply.
4. Replace the system board
Location: P1
1. Power supply
Location: V3
2. System board
Location: P1
1. Power supply
Location: V3
2. System board
Location: P1
1. Power supply
Location: V3
2. System board
Location: P1
Power supply, Location: V3
Processor unit, Location: P1-C1
1. Processor unit
Location: P1-C1
2. System board
Location: P1
Processor unit, Location: P1-C1
Processor unit, Location: P1-C1
1. Processor unit
Location: P1-C1
2. System board
Location: P1
Processor unit, Location: P1-C1