Table 7. Service Processor Error Codes (continued)
Error Code
4069 0009
4069 00A0
4069 00A1
4069 00A2
4069 00A3
4069 00A4
4069 00A5
4069 00A6
4069 00A7
4069 00B0
4069 00B1
4069 00B7
4069 0100
154
Service Guide
Description
Memory tests detected memory fault
Memory tests detected service
processor firmware fault
Memory tests detected system
firmware fault
Memory tests detected service
processor firmware (PRD) fault
Memory tests detected memory
plugging fault
Memory tests detected application
caused fault
Memory tests detected invalid system
configuration
Memory tests detected no usable
memory
Memory tests detected hardware
problem
Memory tests detected bus controller
lock-unlock failure
Memory tests diagnostics detected
bus controller failure
Memory test detected insufficient
hardware resources to continue IPL
Memory tests detected memory riser
card fault
Action/ Possible Failing FRU
Go to "MAP 1540: Minimum
Configuration" on page 57.
Update system firmware
1. Check for AIX updates
2. Check for system firmware
updates
Update system firmware
Go to "MAP 1540: Minimum
Configuration" on page 57.
Application software
Verify that system components are
supported and properly installed
1. Ensure that memory is properly
installed
2. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 268 for more
information.
3. Go to "MAP 1540: Minimum
Configuration" on page 57
4. If the problem is not fixed, call
service support.
Go to "MAP 1540: Minimum
Configuration" on page 57.
System board, Location: P1
System board, Location: P1
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
Memory riser card Location: P1-M2