IBM F80 Service Manual page 149

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 6. Firmware Error Codes (continued)
Error Code
Description
25A8 0211
Setenv/$Setenv parameter error -
value contains a null character.
25A8 0998
NVRAMRC script evaluation error -
command line execution error
25A8 0999
NVRAMRC script evaluation error -
stack unbalanced on completion
Action/ Possible Failing FRU
Refer to Action under error code
25A80xxx.
Execution of a command line within
the nvram configuration variable
"nvramrc" (script) resulted in a
"throw" being executed. This script
can be modified by the system
firmware SMS utilities, the operating
system, PCI adapter ROM code or
utility, or an operator (via the open
firmware script editing command
"nvedit"). It may not be possible to
resolve the problem without a
detailed analysis of the nvram script,
the current system configuration, and
device tree contents.
1. The problem can be caused by a
SCSI adapter, whose SCSI bus
ID has been changed from the
default setting, no longer
appearing in the system. This can
be caused either by removing a
SCSI adapter, or a problem with
a SCSI adapter.
a. Select the SCSI ID utility from
the SMS menu(s).
1) Verify the list of SCSI
controllers/adapters. If the
list is not correct, suspect
a problem with the
adapter(s) installed but
not listed.
2) Select the option to save
the configuration
information.
3) Restart the system.
b. If the problem persists, boot
the operating system and
verify the SCSI bus IDs of
any installed/available SCSI
controllers (change as
necessary), and restart the
system.
2. Contact your support
representative for further
assistance.
This is a firmware debug environment
error. There is no user action or FRU
replacement for this error.
Chapter 5. Error Code to FRU Index