Table 7. Service Processor Error Codes (continued)
Error Code
Description
4506 25BF
Memory system and scan interface
basic assurance tests detected 6W
668 MHz processor fault
4506 25CB
1W processor card fault
4506 25EA
4W processor card fault
4506 25EB
2W processor card fault
4506 25F2
6W processor card fault
4506 263D
Memory system and scan interface
basic assurance tests detected
memory filler fault
4506 281F
Memory system and scan interface
basic assurance tests detected SSA
backplane fault
4506 282E
Memory system and scan interface
basic assurance tests detected
system board fault
4506 283F
Memory system and scan interface
basic assurance tests detected SCSI
backplane fault
4506 288D
Memory system and scan interface
basic assurance tests detected
memory riser fault
4506 2A00
Memory system and scan interface
basic assurance tests detected 6W
4M 500 MHz processor fault
4506 300A
Memory system and scan interface
basic assurance tests detected 32MB
DIMM fault
4506 300B
Memory system and scan interface
basic assurance tests detected
128MB DIMM fault
4506 300C
Memory system and scan interface
basic assurance tests detected
256MB DIMM fault
Action/ Possible Failing FRU
Processor card, Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1 (See
note 3 on page 41.)
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
1. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See "Memory
Configuration/Deconfiguration
Menu" on page 268 for more
information.
2. Memory riser card, Location:
P1-M1 or P1-M2 or P1-C1
Processor card, Location: P1-C1
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index
185