Table 7. Service Processor Error Codes (continued)
Error Code
406B 0113
406B 0114
406B 011D
406B 0121
406B 0122
406B 0123
406B 0124
406B 012D
406B 0131
406B 0132
406B 0133
406B 0134
406B 013D
406B 01FF
406B 0200
406B 0201
406B 0202
406B 0203
406B 0204
406B 020D
164
Service Guide
Description
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory failure
on riser card 2 that cannot be
automatically isolated.
Wire tests detected memory riser
card fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Wire tests detected memory DIMM
fault
Action/ Possible Failing FRU
Memory DIMM Location: P1-M2.14
Memory DIMM Location: P1-M2.4
Memory DIMM Location: P1-M2.3 x4
Memory DIMM Location: P1-M2.11
Memory DIMM Location: P1-M2.5
Memory DIMM Location: P1-M2.12
Memory DIMM Location: P1-M2.6
Memory DIMM Location: P1-M2.5 x4
Memory DIMM Location: P1-M2.9
Memory DIMM Location: P1-M2.7
Memory DIMM Location: P1-M2.10
Memory DIMM Location: P1-M2.8
Memory DIMM Location: P1-M2.7 x4
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
Memory DIMM Location: P1-M1
Memory DIMM Location: P1-M1.15
Memory DIMM Location: P1-M1.1
Memory DIMM Location: P1-M1.16
Memory DIMM Location: P1-M1.2
Memory DIMM Location: P1-M1.1 x4