Table 5. SPCN Error Codes (continued)
Error Code
Description
1011 1513
Power supply 1
1011 1514
Power supply 1
1011 1516
Power supply 1 missing
1011 1520
Power supply 2 ac source failure
1011 1521
Power supply 2
1011 1522
Power supply 2 non-power fault
1011 1523
Power supply 2 domain fault
1011 1524
Power supply 2 cooling fault
1011 1526
Power supply 2 missing
1011 1530
Power supply 3 ac source
Action/ Possible Failing FRU
1. Power supply,
Location: V1
2. System board
Location: P1
1. Power supply,
Location: V1
2. System board
Location: P1
Power supply, Location: V1
1. Check power input to power
supply.
2. Power supply, Location: V2
3. System board, Location: P1
1. Power supply 2
Location: V2
2. If the problem is not resolved,
reinstall the original supply in
location V2. Then replace power
supply 1, location V1, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 3 (if present), location V3,
with the new supply.
4. Replace the system board
Location: P1
1. Power supply
Location: V2
2. System board
Location: P1
1. Power supply
Location: V2
2. System board
Location: P1
1. Power supply
Location: V2
2. System board
Location: P1
Power supply, Location: V2
1. Check power input to power
supply.
2. Power supply, Location: V3
3. System board, Location: P1
Chapter 5. Error Code to FRU Index
111