IBM F80 Service Manual page 233

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 7. Service Processor Error Codes (continued)
Error Code
Description
460C 300A
I/O system and IPL detected 32MB
DIMM fault
460C 300B
I/O system and IPL detected 128MB
DIMM fault
460C 300C
I/O system and IPL detected 256MB
DIMM fault
460C 300D
I/O system and IPL detected 512MB
(stacked) DIMM fault
460C 300E
I/O system and IPL detected 512MB
(unstacked) DIMM fault
460C 301F
I/O system and IPL detected 128MB
DIMM fault
460C 303A
I/O system and IPL detected 1GB
DIMM fault
460D 244C
I/O system and attention handler
detected 1W 2M 400 MHz processor
fault
460D 244D
I/O system and attention handler
detected 2W 4M 500 MHz processor
fault
460D 244E
I/O system and attention handler
detected 4W 4M 500 MHz processor
fault
460D 244F
I/O system and attention handler
detected 1W 2M 500 MHz processor
fault
460D 248A
I/O system and attention handler
detected operator panel fault
460D 24A1
I/O system and attention handler
detected 1W 2M 450 MHz processor
fault
460D 24A2
I/O system and attention handler
detected 2W 450 MHz processor
fault
460D 24A3
I/O system and attention handler
detected 4W 450 MHz processor
fault
460D 24A4
I/O system and attention handler
detected 6W 500 MHz processor
fault
460D 25B6
I/O system and attention handler
detected 650W power supply fault
Action/ Possible Failing FRU
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Operator panel, Location : L1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Chapter 5. Error Code to FRU Index
215

Advertisement

Table of Contents
loading

Table of Contents