Ssa Loop Configurations That Are Not Valid - IBM F80 Service Manual

Rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 12. Service Request Numbers (continued)
SRN
FRU List
D0450
None
D0460
None
D4000
SSA adapter card (See the
installation and service guide for the
using the system.)
D4100
SSA adapter card (See the
installation guide and the service
guide for the using system.)
D4300
SSA adapter card (See the
installation guide and the service
guide for the using system.)
D44xx
SSA adapter card (See the
installation guide and the service
guide for the using system.)
DFFFF
SSA adapter card (See the
installation guide and the service
guide for the using system.)
D6PAA
through
SSA03

SSA Loop Configurations That Are Not Valid

Note: This section is related to SRN 48000.
436
Service Guide
%
Problem
Description: A format operation is in progress.
The format operation that was started on this disk
drive module has not yet finished. A format
operation can take up to 30 minutes to run.
Action: Wait for the format operation to finish
before you run the diagnostics again. You can
observe the progress of the format operation by
running the format service aid again on this disk
drive module.
Description: A format operation has been
degraded. The format operation that was started
on this disk drive module did not finish. Possibly,
the disk drive module was switched off while the
format operation was running.
Action: Run the format service aid to format this
disk drive module.
100
Description: The diagnostics cannot configure
the SSA adapter.
Action: Exchange the FRU for a new FRU.
100
Description: The diagnostics cannot open the
SSA adapter.
Action: Exchange the FRU for a new FRU.
100
Description: The diagnostics have detected an
SSA adapter POST failure.
Action: Exchange the FRU for a new FRU.
100
Description: The diagnostics have detected that
the SSA adapter has corrupted the microcode,
but cannot download a new version of the
microcode.
Action: Exchange the FRU for a new FRU.
Note: In this SRN, an x represents a digit 0
through F.
100
Description: A command or parameter that has
been sent or received is not valid. This problem is
caused either by the SSA adapter or by an error
in the microcode.
Action: Go to "Software and Microcode Errors"
on page 428 before exchanging the FRU.
Action: Go to Advanced SerialRAID Adapters
User's Guide and Maintenance Information, order
number SA33-3285.

Advertisement

Table of Contents
loading

Table of Contents