Table 7. Service Processor Error Codes (continued)
Error Code
Description
406E 030D
Scan control routines detected
memory DIMM fault
406E 0311
Scan control routines detected
memory DIMM fault
406E 0312
Scan control routines detected
memory DIMM fault
406E 031D
Scan control routines detected
memory DIMM fault
406E 0321
Scan control routines detected
memory DIMM fault
406E 0322
Scan control routines detected
memory DIMM fault
406E 032D
Scan control routines detected
memory DIMM fault
406E 0331
Scan control routines detected
memory DIMM fault
406E 0332
Scan control routines detected
memory DIMM fault
406E 033D
Scan control routines detected
memory DIMM fault
406E 03FF
Scan control routines detected
memory failure on processor card
that cannot be automatically isolated.
406E 3101
Scan control routines detected RIO
port 0 fault
406E 3281
Scan control routines detected RIO
port 0 fault
406E 3284
Scan control routines detected PCI
controller PHB0 fault
406E 3285
Scan control routines detected PCI
controller PHB1 fault
406E 3286
Scan control routines detected PCI
controller PHB2 fault
406F 0001
Error code generation/logging
detected system board fault
406F 0003
Error code generation/logging
detected processor fault
406F 0009
Error code generation/logging
detected memory fault
406F 00A0
Error code generation/logging
detected service processor firmware
fault
Action/ Possible Failing FRU
Memory DIMM Location: P1-C1-M1
x2
Memory DIMM Location: P1-C1-M7
Memory DIMM Location: P1-C1-M2
Memory DIMM Location: P1-C1-M2
x2
Memory DIMM Location: P1-C1-M6
Memory DIMM Location: P1-C1-M3
Memory DIMM Location: P1-C1-M3
x2
Memory DIMM Location: P1-C1-M5
Memory DIMM Location: P1-C1-M4
Memory DIMM Location: P1-C1-M4
x2
Go to "MAP 1540: Minimum
Configuration" on page 57, and run
minimum configuration for further
isolation.
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
Replace the system board. Location:
P1 (See note 3 on page 41.)
All processors, Location: P1-C1
Go to "MAP 1540: Minimum
Configuration" on page 57.
Update system firmware
Chapter 5. Error Code to FRU Index
179