6-12. SOLENOID VALVES
409
Each vat has a solenoid plumbed-into the oil return lines. They
are normally closed, but open when power is supplied, such as,
the controls are fi lling the vats.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Remove control panel and hinge it down.
2. Refering to the decal on the rear of the control panel, locate
P3 connector (left vat-split vat) or P4 connector (full or right
vat).
3. Pull the connector from the panel and using a multmeter,
take an ohm reading on the appropriate pins. If ohm read-
ing is signifi cantly different than the chart below, continue
with replacement instructions.
120Volts-60Hertz
220-240Volts-50Hertz
Replacement
1. Remove the rear panel (9 screws).
2. Remove the plastic retaining clip on top of the coil housing.
3. Push-down and then lift-up on name-plate and remove the
name-plate, cover and coil housing from solenoid stem.
4. Using a 1" wrench, loosen the fi tting on the right side of the
solenoid.
Model EEE-153, 154
50 Ohms
230 Ohms
6-14