Problem
With power switch in
ON position, the fryer
is completely inoperative
(NO POWER)
Oil will not heat
409
Cause
POWER SECTION
•
Open circuit
HEATING OF SHORTENING SECTION
•
Blown fuse or tripped
•
Faulty power switch.
•
Faulty cord and plug
•
Faulty drain switch
•
Faulty PC Board
•
High limit control switch tripped
Model EEE-153, 154
Correction
•
Check to see that unit is plugged in
•
Check the breaker or fuse
at supply box
•
Check voltage at wall receptacle
•
Check MAIN POWER
switch; replace if defective
•
Check cord and plug
• Check circuit breakers in fryer
•
Reset breaker or replace fuse
circuit breaker at supply
box or control panel
•
Check power switch
per maintenance section on
the power switch
•
Check cord and plug
• Check power at receptacle
•
Check drain switch per
maintenance section on
drain switches
•
Remove and replace control panel
• Reset the high limit by using a
small screwdriver or Allen
wrench, gently pushing it into the
hole in the heating element hinge;
if high limit does not reset, high
limit must be replaced
1-3