6-11. CONTACTORS
(Continued)
Heat contactor ohm check
6-13
4. With power reapplied and in a heat-up mode, check the
power going to both contactor coils. Power should be
going to both contactors.
If no voltage is found going into the primary contactor coil,
check wiring, high limit, and element switch.
If no voltage at heat contactor coil check wiring and
connections at PC board.
Replacement
If either contactor proves defective, replace as follows:
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
1. Label and remove only those wires directly connected to
the contactor being replaced.
2. Using a 3/8" wrench or socket, remove the 2 mounting nuts
on the base plate of the contactor being replaced and
remove contactor.
3. When replacing the heat contactor, slide it from the
mounting rail.
4. Install new contactor in reverse order.
5. Replace rear panel and reconnect power to the fryer and
test for proper operation.
Model EEE-153, 154
409