Henny Penny Evolution Elite EEE-153 Technical Manual page 39

Reduced oil capacity open fryers (split vat & full vat– electric)
Hide thumbs Also See for Evolution Elite EEE-153:
Table of Contents

Advertisement

5-5. TECH MODE (Continued)
409
Press
button and "AIF REQ" and "RQ=Y OK=Y" shows
in the displays.
REQ=Y" means that this particular control is currently request-
ing control of the AIF Board outputs.
"OK=Y" means that the AIF Board has granted this control the
authority to control the AIF Board outputs.
Press
button and "FILR IN" and "USE BY 1(ex)" shows
in the displays. These displays shows which controls are using
the fi ltering system.
"USE = 0" = not in use
"USE = 7" = used by AIF
"USE = 1 to 5" = used by control PCB
Press
button and "CPU POSN" and "1 OF 3(ex)" shows in
the displays. These displays shows which controls are plugged
into which port on the AIF board.
For example, the left control should be plugged into port 1, and
on a 3 control fryer, shows "1 OF 3" on the display.
If the right control is unplugged, then the left control would show
"1 OF 2" instead of "1 OF 3".
Press
button and "INP E_P_" and "JL_Rx DF_" shows
in the displays.
AIF Board Inputs:
E = Stop button
P = Drain Pan
JL = JIB
R = RTI
DT = Discard Tank
Model EEE-153, 154
Ex = E-Stop pressed.
Px = drain pan is missing.
Jx = JIB oil level is low.
Rx = RTI System NOT Detected
DTx = tank full
5-16

Hide quick links: