6-12. SOLENOID VALVES
(Continued)
6-15
5. Pull the elbow away from the 1" nut, and using a 1-1/16"
wrench or adjustable wrench, hold the solenoid in place
while using another wrench to remove the elbow from the
solenoid. Attach elbow to new solenoid, using pipe sealent
on the threads.
6. Pull the coil housing from the solenoid stem. Hold the pipe
nipple in place with a pipe wrench and using a 1-1/16"
wrench or adjustable wrech, remove the solenoid from the
nipple.
7. Remove the conduit from the fryer and pull the coil
assembly from the fryer.
8. Disconnect conduit at coil.
9. Thread the wires of the new solenoid through the conduit
and reattach the conduit to the fryer.
10. Wire nut the solenoid wires onto the fryer wires, and then,
attach the solenoid assembly onto the fi ttings of the fryer.
11. Replace rear cover and reconnect power to the fryer.
Model EEE-153, 154
409